The HTI BioChem FC-120 is a fully auto biochemistry electrolyte analyzer with random access chemistry system with STAT capability Low volume of sample laboratories
Fully automated, random access chemistry system with STAT capability Low volume of sample laboratories
System Function
Throughput: up to 100 test/hour
Assay Type: End-Point, Kinetic, Fixed-Time, Single/Dual Reagent, Monochromatic, Bichromatic
Measuring Principles: Colorimetric, Kinetic, Turbidimetric
Sample Type: Plasma, Serum, Whole Blood, Urine, CSF
Programming: User defined profiles and calculation, method defined washing programs
Reagent/Sample Handling
Reagent/Sample Tray: 9-42 positions for primary tubes (12x17mm) and sample cups. 26 positions for R1, 13 positions for R1/R2
Sample Volume: 3ul ~ 45ul, increments 0.5ul
Reagent Volume: R1: 180ul ~ 450ul, R2: 3 ~ 450ul increments of 1ul
Reagent/Sample Probe: Liquid Level Detection, Collision protection, Reagent Volume Check, Reagent/Sample Pre-Heating 37°C
Probe Cleaning: Interior and exterior automatic probe washing, Carry-Over < 2%
Reaction System
Reaction Rotor: Rotating tray, 90 disposable cuvettes (9 Segments)
Cuvette: Optical Length 5mm
Reaction Volume: 180 ~ 500ul
Operating Temperature: Ambient, 30°C, 37°C
Temperature Fluctuation: ± 0.1°C
Mixing: Mixer part of Reagent/Sample Handling Assay
Optical System
Light Source: Halogen Lamp 12V 20W
Wavelength: 340, 405, 450, 510, 546, 578, 630, 670nm
Absorption Rate: 0.0 ~ 3.5Abs
Resolution: 0.0001Abs
Control and Calibration
Calibration Mode: Factor, One-Point Linear, Multi-Point Linear, Multi-Point Non-Linear, Log Linear, Exp Linear, Logistics-Log 4P, Logistics-Log 5P, Exponential 5P, Polynomial 5P, Parabola, Spline
Quality Control: Levy-Jennings, Westgard Multi-Rule
Software
LIS: Bi-Directional
Languages: English, Spanish, Russian, Ukrainian
Data Storage:
Printing: Internal Printer, External Printer available on any Windows compatible Printer
Statistics: Test, Quality Control, Calibration Counter
Re-Run: Automatic Sample
Dilution: Automatic Sample Dilution
Working Condition
Power Supply: 100 ~ 240 VAC, 50/60Hz, 350VA
Temperature: 20 ~ 30°C Humidity: 40 ~ 85%
Water Consumption: ≤ 3 Liter/Hour
Dimension: 63cm x 48cm x 51cm (W x H x D)
Weight: 70kg
Kencare Medical Systems Limited is a Kenya-based leading distributor of medical devices. Our goal is to provide the best quality products.
Phone: +254 737 320000
Email: [email protected]
Address: Lunga Lunga Square, 3rd Floor, Unit 332, Lunga Lunga Road, Nairobi, Kenya.